  reference only product specification for reference only issued date: april 30 , 201 5 rev. : n p ar t d e s c r i p t i o n : u l t r a s o n i c t r a n s d u c e r m u r a t a p ar t n o . : m a 4 0 s 4 r the product specification in this sheet is for reference only. the contents of this specification are subject to change. you are requested to receive the latest specification and to return one copy of the specification to us with your receipt signature be fore going into mass production. sensor products department 1 sensor products division murata manufacturing co., ltd.
reference only p 1 / 6 m urata manufacturing co., ltd. rev . n reference s pecification of ultrasonic transducer type: ma40s4r 1. scope this product specification is applied to the receiver of ultrasonic transducer (open type structure). 2. customer part number 3. murata part number ma40s4 r 4. structure dimension : a s per fig.1 5. absolute maximum ratings items specification note 5 - 1 operating temperature range - 40 to +85 degc - 5 - 2 storage temperature range - 40 to +85 degc - 6. specifications (* temperature 25 3 c, 45 to 7 5 % r.h, unless otherwise noted ) items specification note 6 - 1 operating frequency 40.0 khz for reference 6 - 2 sensitivity - 63 db +/ - 3 db at 40 khz / 0 db = 10 v/pa (per measuring circuit fig.2) 6 - 3 capacitance 2 , 550 pf +/ - 20 % at 1 khz 6 - 4 insulation resistance m ore than 100 m ohm at 50 v d.c. 6 - 5 temperature characteristics w ithin +/ - 3db against initial value at 25 degc - 40 to +85 degc
reference only p 2 / 6 m urata manufacturing co., ltd. rev . n 7. environmental tests (standard test condition: 25 +/ - 3 degc , 45 to 75 %r.h) 7.1 shock test the variation of the sensitivity at 40 khz is within +/ - 3 db compared with initial stage at 25 degc after applied following test conditions acceleration : sine 980 m/s 2 (100 g), 6 ms direction : 3 directions shock time : 3 times / directions 7.2 vibration test the variation of the sensitivity at 40 khz is within +/ - 3 db compared with initial stage at 25 degc after applied following test conditions vibrat ion frequency : 10 to 55 hz sweep period : 1 min. amplitude : 1.5 mm directions : 3 directions time : 2 hours / direction 7.3 resistance to soldering heat the variation of the sensitivity at 40 khz is within +/ - 3 db compared with initial stage at 25 degc in 1 hour after touching soldering iron (iron temperature : 350 degc), 3 seconds with the termi nal. (touching point must be 2mm or more away from the transducer body.) 7.4 high temperature test the variation of the sensitivity at 40 khz is within +/ - 3 db compared with initial stage at 25 degc in 24 hours after applied following test conditions temperature : +85 +/ - 2 degc time : 100 hours 7.5 low temperature test the variation of the sensitivity at 40 khz is within +/ - 3 db compared with initial stage at 25 degc in 24 hours after applied following test conditions temperature : - 40 +/ - 2 degc time : 100 hours 7.6 humidity test the variation of the sensitivity at 40 khz is within +/ - 3 db compared with initial stage at 25 degc in 24 hours after following test conditions temperature : +60 +/ - 2 degc humidity : 90 to 95 % r.h. time : 100 hours 7.7 pull strength there should be no substantial damage until 9.8 n pulling force .
reference only p 3 / 6 m urata manufacturing co., ltd. rev . n 8. caution 8 - 1 limitation of applications please do not use in the applications listed below which require a high reliability to prevent the defects which might cause a damage to the peoples life and/or property. 1) aircraft equipment 2) aerospace equipment 3) undersea equipment 4) power plant control equipment 5) medical equipment 6) tra nsportation equipment (trains, ships, etc.) 7) traffic signal equipment 8) disaster prevention / crime prevention equipment 9) data - processing equipment 10) military equipment (regardless of directly/indirectly) 11) security device/system 12) outside - usage, in which the transducer is exposed to splashes or dusts 13) application of similar complexity and/or reliability requirement to the applications listed in the above 8 - 2 fail - safe please make sure to provide an appropriate fail - safe function on your product to prevent a second d amage that may be caused by the abnormal function or the failure of our product. 9. caution in use 9 - 1 (notice in design and usage) 1) the transducer may generate surge voltage by mechanical or thermal shock. 2) please do not apply d.c. voltage for ultrasonic transducer to avoid migration. 3) please do not use this ultrasonic transducer in water. 4) please do not apply an excess i ve mechanical shock or force on the top of this ultrasonic transducer and terminal pins. it may cause of disconnection and malfunction. 5) please d o not use nor storage this ultrasonic transducer in heavy dust condition. it may be a cause of clogging and low performance. also, please do not use this transducer in high humidity or high concentrated exhaust gas. it may be a cause of corrosion and malfunction. 6) care should be taken when select the material to hold, or cover backside of transducer. if it contains sulfur or sulfide, electrode on piezo - electric element may be corroded and bec ame malfunction. 7) this transducer does not have a definition of terminal po larity. please check a signal before using if you need a signal phase control for your application. 9 - 2 ( notice in storage) 1) the products should not be used or stored in a corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. store the products in the room where is normal temperature and humidity, and avoid the sunlight, sudden changes in temperature and humidity. it may cause of failure or malfunction in such conditions. 2) store the products where the temperature and relative humidity do not exceed - 10 to 40 deg c , and 30 to 80 %rh. use the products within 6 months after receiving. 9 - 3 (notice in mounting) 1) please do not apply excessive force to terminals, when soldering. 2) please use soldering tempera ture with not exceeds 350 degc , 3 second s . 3) flow soldering is not applicable. 4) please do not clean by water and dissolving agent. 5) this product cannot be used mounted on pcb. soldering fillet at the bottom of case may interfere with throughhole of pcb. please contact products engineering section of murata if you will use this product mounted on pcb.
reference only p 4 / 6 m urata manufacturing co., ltd. rev . n 10. note 1) please make sure that your product has been evaluated in view of your specifications with our product being mounted to your product. 2) you are requested not to use our product deviating from t h e agreed specifications. 3) we consider inappropriate to include any terms or conditions with regard to the business transaction in the product specifications, drawings or other technical docu ments. therefore, if your technical documents as above include such terms and conditions such as warranty clause, product liability clause, or intellectual property infringement liability clause, they will be deemed to be invalid. dimensions fig.1 : product dimension caution) there is a fillet of solder in this area. please refer to 9 - 3 (notice in mounting) (2.0) () : reference value prohibited area of customer soldering 5.0 0. 3 2 - 0.64 0.1 7.1 0.3 dia. 9.9 0.3 10.0 1.0 lot no. 6 d igits x x x x xx unit: mm. r xxxxxx year (1 digit) month (1 digit) serial number (4 digits) 0~9 (cycle 10 years) jan.~sep. 1 ~ 9 0001~9999 ex.. 2013 3 oct. x 2014 4 nov. y 2015 5 dec. z 2016 6 run number is reset every month.
reference only p 5 / 6 m urata manufacturing co., ltd. rev . n measuring c ircuit fig. 2 : murata standard measuring condition : u.s. and s.c.m must be aligned with the line of sp., and fixed distance: 30 cm when measuring . an i nput sound pressure level is 94 db at 40 khz. h o w to measure a temperature characteristic : a fter inputting a product into the thermostatic chamber in 15 min . or more, m easure the product according to the above method immediately sp. s.c.m. 30 cm u. s. amp. osc. freq. counter voltmeter osc. : oscill ator (brel & kj?r 1013 ) u. s. : ultrasonic sensor s. c.m : standard condenser microphone (brel & kj?r 4135) amp. : amplifier (brel & kj?r 26 10 ) sp. : tweeter r l : 3.9 k ohm rl


▲Up To Search▲   

 
Price & Availability of MASPOPRE

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X